← Physiology models and case processes
Simulator reference
Heart-rate variability (RSA and drift)
Fast and slow drift plus RSA 2 bpm, damped by sedation and falling with intracranial compromise.
Sources the model was built from
- Unbehaun A, Mrowka R, Schubert E, et al. Interaction of heart-rate fluctuations and respiration in 12 to 14-year-old children during sleeping and waking. J Auton Nerv Syst. 1996;57(3):141-3.
- Lubocka P, Sabiniewicz R. Respiratory Sinus Arrhythmia in Children-Predictable or Random?. Front Cardiovasc Med. 2021;8:643846.
Related literature
Each paper was checked against this feature by independent automated reviewers before being listed. The reviewers worked from findings extracted from the paper; a clinician has not read each one.
- Andersen M, Andelius TCK, Pedersen MV, et al. Severity of hypoxic ischemic encephalopathy and heart rate variability in neonates: a systematic review. BMC Pediatr. 2019;19(1):242.
- Task Force of the European Society of Cardiology the North A Electrophysiology. Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use. Circulation. 1996;93(5):1043-1065.
- Pinto SM, Wright B, Annaswamy S, et al. Heart rate variability (HRV) after traumatic brain injury (TBI): a scoping review. Brain Inj. 2024;38(8):585-606.
- Statello R, Carnevali L, Sgoifo A, et al. Heart rate variability in neonatal seizures: Investigation and implications for management. Neurophysiol Clin. 2021;51(6):483-492.
- Sykora M, Czosnyka M, Liu X, et al. Autonomic Impairment in Severe Traumatic Brain Injury: A Multimodal Neuromonitoring Study. Crit Care Med. 2016;44(6):1173-81.
- Pendergrast TR, Chapin CA, Kriegermeier AA, et al. Heart rate variability is associated with encephalopathy and outcomes in pediatric acute liver failure. Pediatr Res. 2023;93(5):1348-1353.
- Myers KA, Sivathamboo S, Perucca P. Heart rate variability measurement in epilepsy: How can we move from research to clinical practice?. Epilepsia. 2018;59(12):2169-2178.
- van Westrhenen A, De Cooman T, Lazeron RHC, et al. Ictal autonomic changes as a tool for seizure detection: a systematic review. Clin Auton Res. 2019;29(2):161-181.
- Mackie DB, Smith CM, Sanchez-Pinto LN, et al. Heart Rate Variability Discriminates Outcomes After Pediatric Cardiac Arrest. Pediatr Crit Care Med. 2026;27(4):447-457.
- Kim SW, Jeon HR, Kim JY, et al. Heart Rate Variability Among Children With Acquired Brain Injury. Ann Rehabil Med. 2017;41(6):951-960.
- Badke CM, Carroll MS, Weese-Mayer DE, et al. Association Between Heart Rate Variability and Inflammatory Biomarkers in Critically Ill Children. Pediatr Crit Care Med. 2022;23(6):e289-e294.
- Garvey AA, Pavel AM, O'Toole JM, et al. Multichannel EEG abnormalities during the first 6 hours in infants with mild hypoxic-ischaemic encephalopathy. Pediatr Res. 2021;90(1):117-124.
All 19 papers
- Arbune AA, Jeppesen J, Conradsen I, et al. Peri-ictal heart rate variability parameters as surrogate markers of seizure severity. Epilepsia. 2020;61 Suppl 1:S55-S60.
- Goulding RM, Stevenson NJ, Murray DM, et al. Heart rate variability in hypoxic ischemic encephalopathy during therapeutic hypothermia. Pediatr Res. 2017;81(4):609-615.
- Sayadi O, Shamsollahi MB, Clifford GD. Synthetic ECG generation and Bayesian filtering using a Gaussian wave-based dynamical model. Physiol Meas. 2010;31(10):1309-29.
- Olmi B, Manfredi C, Frassineti L, et al. Heart Rate Variability Analysis for Seizure Detection in Neonatal Intensive Care Units. Bioengineering (Basel). 2022;9(4).
- Aboy M, McNames J, Hornero R, et al. A novel statistical model for simulation of arterial and intracranial pressure. Conf Proc IEEE Eng Med Biol Soc. 2004;2006:129-32.
- Chock VY, Rao A, Van Meurs KP. Optimal neuromonitoring techniques in neonates with hypoxic ischemic encephalopathy. Front Pediatr. 2023;11:1138062.
- Drago F, Battipaglia I, Di Mambro C. Neonatal and Pediatric Arrhythmias: Clinical and Electrocardiographic Aspects. Card Electrophysiol Clin. 2018;10(2):397-412.
Editorial draft · clinical review pending. A teaching model, not calibrated to an individual child.