RPP term construction and validity boundary

An RPP name combines one localization main term with one pattern-type main term, then adds applicable modifiers.

Criteria & assessment

required components
  • one main_term_1 localization
  • one main_term_2 pattern type
minimum run
consecutive cycles min
6
examples
  • 1 Hz for 6 s
  • 3 Hz for 2 s
frequency boundary
No RPP may have a typical frequency above 4 Hz. A pattern above 4 Hz lasting at least 0.5 s is outside this RPP contract; one shorter than 0.5 s is not an RPP.
evolution boundary
Within RPP terminology, evolution is limited to patterns at or below 4 Hz and shorter than 10 s. Longer evolving patterns and faster short patterns are delegated to the seizure/BIRD contracts.
Generation & measurement notes
  • Represent boundary handoffs as validation failures or external labels; do not derive seizure, BIRD, or IIC labels here.