Stimulus state, evolution, fluctuation, and static modifiers
Stimulus modifiers describe reproducible response to alerting stimulation; temporal modifiers describe frequency, morphology, or location change.
Criteria & assessment
- stimulus state
- SI
- Reproducibly brought about or exacerbated by alerting stimulus in a less-stimulated state, with or without clinical alerting; may also occur spontaneously.
- ST
- Reproducibly terminated or attenuated by alerting stimulus in a less-stimulated state, with or without clinical alerting; may also self-terminate.
- spontaneous
- Never clearly induced, exacerbated, improved, or terminated by stimulation.
- unknown
- Unclear or untested.
- stimulus type required
- auditory
- light tactile
- patient care/other nonnoxious
- noxious
- evolving
- minimum
- At least 2 unequivocal sequential changes in the same category.
- frequency
- Two consecutive changes in one direction, each at least 0.5 Hz; each frequency persists at least 3 cycles.
- morphology
- Two consecutive novel morphologies; each morphology, including transition forms, persists at least 3 cycles.
- location
- Sequential spread into or out of at least 2 standard 10-20 electrode locations; involvement of each additional electrode persists at least 3 cycles.
- interstep gap
- Reach criteria without the changing feature remaining unchanged for 5 or more continuous minutes.
- amplitude
- Voltage/amplitude change alone is neither evolution nor a new morphology.
- fluctuating
- minimum
- At least 3 changes, no more than 1 minute apart, not qualifying as evolution.
- frequency
- Each change at least 0.5 Hz; each frequency persists at least 3 cycles.
- morphology
- Each morphology persists at least 3 cycles.
- location
- Each change at least 1 standard interelectrode distance; each location persists at least 3 cycles.
- amplitude
- Voltage/amplitude change alone is not fluctuation.
- static
- Neither evolving nor fluctuating.
- additional reporting
- If evolving or fluctuating in frequency, specify minimum and maximum frequency. For nongeneralized patterns specify spread as none, unilateral, or bilateral.
Source · 2021ACNS critical-care EEG terminology · PDF p. 14 ↗
Evolution · EEG 16 · PDF p. 17 ↗Fluctuation · EEG 17 · PDF p. 18 ↗Generation & measurement notes
- Use an event sequence rather than a single classifier score so cycle persistence, direction, and interstep gap can be audited.