Skip to main content
← Critical-care EEG

Continuity and low-voltage percent

Continuity category from percent of a record/epoch occupied by attenuation or suppression.

Criteria & assessment

  • Attenuation: lower activity >=10 µV and <50% of higher-voltage background; suppression: lower activity <10 µV.
  • Continuous: low-voltage percent <1%.
  • Nearly continuous: 1–9%, with qualifying periods >=1 s; report typical duration.
  • Discontinuous: alternating higher activity with 10–49% attenuation/suppression.
  • Burst attenuation/suppression: alternating higher activity with 50–99% attenuation/suppression.
  • Suppression/attenuation: >99%; suppressed when all activity <10 µV, attenuated when all activity <20 µV but not suppressed.
  • For noncontinuous records report attenuation or suppression percent using record/epoch as denominator.
  • Stimulus-induced periods are SI-attenuation or SI-suppression.
Generation & measurement notes
  • Fix analysis epoch, boundaries, and handling of mixed attenuation plus suppression.

Editorial draft · clinical review pending